JAPMA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chuter, V.
Right arrow Articles by Miller, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chuter, V.
Right arrow Articles by Miller, K.
Journal of the American Podiatric Medical Association
Volume 93 Number 1 1-5 2003
Copyright © 2003 American Podiatric Medical Association

Variability of Neutral-Position Casting of the Foot

Vivienne Chuter, BPod(Hons)*, Craig Payne, DipPod, MPH* and Kathryn Miller, BPod*

* Department of Podiatry, School of Human Biosciences, La Trobe University, Melbourne, Australia.

Corresponding author: Craig Payne, DipPod, MPH, Department of Podiatry, School of Human Biosciences, La Trobe University, Bundoora, Victoria 3083, Australia.

Abstract

Neutral-position casting of the foot is used for the manufacture of functional foot orthoses, and an accurate cast is widely assumed to be a prerequisite for a good orthotic device. The primary aim of this study was to determine the variability of casting between inexperienced and experienced clinicians and the variability of one experienced clinician taking multiple casts. Ten inexperienced and ten experienced clinicians took a cast of the right foot of a single subject, and a single experienced clinician took ten casts of the same foot. The frontal plane forefoot-to-rearfoot relationship of each cast was determined, and no difference was found in the mean and variances among the three groups. The range of the forefoot-to-rearfoot relationship across all groups was from 10.0° everted to 6.5° inverted, indicating that there is a wide range in neutral-position casting of the foot. As outcome studies have reported the successful outcomes of functional foot orthoses, this wide variability may not necessarily be a problem. (J Am Podiatr Med Assoc 93(1): 1-5, 2003)




This article has been cited by other articles:


Home page
J. Am. Podiatr. Med. Assoc.Home page
L. C. Trotter and M. R. Pierrynowski
Ability of Foot Care Professionals to Cast Feet Using the Nonweightbearing Plaster and the Gait-Referenced Foam Casting Techniques
J Am Podiatr Med Assoc, January 1, 2008; 98(1): 14 - 18.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Podiatr. Med. Assoc.Home page
N. A. Guldemond, P. Leffers, A. P. Sanders, H. Emmen, N. C. Schaper, and G. H. I. M. Walenkamp
Casting Methods and Plantar Pressure: Effects of Custom-made Foot Orthoses on Dynamic Plantar Pressure Distribution
J Am Podiatr Med Assoc, January 1, 2006; 96(1): 9 - 18.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Podiatric Medical Association.