JAPMA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Domínguez, G.
Right arrow Articles by Munuera, P. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Domínguez, G.
Right arrow Articles by Munuera, P. V.
Journal of the American Podiatric Medical Association
Volume 98 Number 5 364-369 2008
Copyright © 2008 American Podiatric Medical Association

Metatarsus Adductus Angle in Male and Female Feet

Normal Values With Two Measurement Techniques

Gabriel Domínguez, PhD * and Pedro V. Munuera, Lic Pod, PhD *

* Department of Podiatrics, University of Seville, Seville, Spain.

Corresponding author: Gabriel Domínguez, PhD, Departamento de Podología, Centro Docente de Fisioterapia y Podología, C/ Avicena, s/n, 41009 Seville, Spain. (E-mail: gdominguez{at}us.es)

Abstract

Background: The literature contains several techniques for calculating metatarsal adductus angle. Most common systems use the fourth metatarsal cuboid joint and the fifth metatarsal cuboid joint. Although both systems are quite different, normal values of metatarsus adductus angle have not been established with each system of measurement.

Methods: Two hundred six radiographic images of feet in dorsoplantar projection were used to measure the metatarsus adductus angle using two different reference points: the joint between the fourth metatarsal and the cuboid and the joint between the fifth metatarsal and the cuboid.

Results: Comparison of the results of the two measurement techniques showed significant differences (P < .05). The values of the metatarsus adductus angle also showed significant differences in men versus women (P < .05). The reliability of the measurements was checked by using an intra- and inter-evaluator test performed by two evaluators.

Conclusion: Data showed the reliability of both systems of measurement, although significant differences in the metatarsal adductus angle mean value were found using these systems of measurement in the same foot. On the other hand, significant differences were found in mean values of metatarsus adductus angle between male and female feet. (J Am Podiatr Med Assoc 98(5): 364–369, 2008)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Podiatric Medical Association.